Technical datasheet

C_in_Hexagone_Small.png

Single-phase or three-phase EV charging station for any electric vehicle with a Type 2 charging connector (identifier C).

Electrical characteristics

Single-phase device

Input

230 V~; 1W+N+PE; 50/60 Hz; 32 Amax; 7.4 kW

Output

230 V~; 1W+N+PE; 50/60 Hz; 32 Amax; 7.4 kW

Three-phase device

Input

230/400 V~; 3W+N+PE; 50/60 Hz; 32 Amax; 22 kW

Output

230/400 V~; 3W+N+PE; 50/60 Hz; 32 Amax; 22 kW

Types of system earthing

TN, TT

Rated impulse withstand voltage (Uimp)

2500 V – OVC II (4000 V and OVC III is achieved with installed SPD)

Rated insulation voltage (Ui)

230/400 V

Rated current of each circuit (Inc)

32 A

Rated peak withstand current (Ipk)

4500 A

Rated conditional short-circuit current of assembly (Icc)

3000 A

Rated short-time withstand current (Icw)

3000 A

Rated diversity factor (RDF)

  • 1 (without load control),

  • 0 to 1 (with proper setup of load control)

Device power consumption

10–15 W (highest measured value of full configuration)

Environmental characteristics

Ingress protection

IP56

Impact protection

IK10

Protection class

Class I equipment

Pollution degree

Pollution Degree 3

Electromagnetic compatibility (EMC)

  • EMC emissions: Class B (residential)

  • EMC immunity: Class A (other than residential)

Frequency bands and radio power

Wi-Fi

Frequency band: 2.4 GHz 

Transmitting power: up to 20.5 dBm (adjustable)

Sub-GHz 

Frequency bands: 169 MHz, 410–510 MHz, 868 MHz, or 915 MHz

Transmitting power: 14 dBm

RFID module

Frequency band: 13.56 MHz (HF)

Transmitting power: up to 8 dBm

(ISO 14443 and ISO 15693)

Other classification and characteristics

AEVCS

Assembly intended for charging stations for electric vehicles

Installation location

Indoor and Outdoor

Mounting method

Stationary equipment, Wall-mounted assembly

Location accessibility

Location with restricted access or non-restricted access

Mechanical resistance

Medium/High

Installation

Must be performed by qualified personnel

Operation

Allowed to ordinary persons

Electrical installation protection

  • Short-circuit protective device(s):
    Appropriate MCB or fuse must be part of electrical installation, installed upstream of the charging station.

  • Protection against electric shock:
    Appropriate RCD must be part of electrical installation, installed upstream of the charging station. 

Dimensions

Dimensions of assembled charging station (in mm)

image-20240229-135419.png

H2 - to the bottom of the cable gland with a spiral

Main unit + Dock

257 × 273 × 115 (W × H1 × D)

Main unit + Output socket + Dock

257 × 401 × 115 (W × H2 × D)

Main unit + Output socket shutter + Dock

257 × 413 × 120 (W × H2 × D)

Main unit + Output Cable + Dock

257 × 387 × 115 (W × H2 × D)

Mass

Mass (assembled charging station)

3.4 kg to 7 kg
(depending on the configuration and cable length)

Temperature

Operational

-25 °C to +85 °C

Ambiental

-25 °C to +50 °C

Storage

-30 °C to +85 °C

 

 

 

 

Warning! Before installing, wiring, handling or accessing the charging station in any way, make sure to read, understand and follow the Safety Guidelines.