Setting: Authorization.AllowOfflineTxForUnknownId Type: Boolean Read/Write: Both Requires restart? Yes Setting: Authorization.AuthorizationTimeout Type: String; Format: time (hh:mm:ss) Min: 00:00:05 Max: 00:05:00 Read/Write: Both Requires restart? Yes Setting: Authorization.AuthorizeRemoteTxRequests Type: Boolean Read/Write: Both Requires restart? Yes Setting: Authorization.CableConnectedTimeout Type: String; Format: time (hh:mm:ss) Min: 00:00:10 Max: 00:30:00 Read/Write: Both Requires restart? Yes Setting: Authorization.CableDisconnectTimeout Type: String; Format: time (hh:mm:ss) Min: 00:00:10 Max: 00:30:00 Read/Write: Both Requires restart? Yes Setting: Authorization.Identifications[Rfid].IsInstalled Type: Boolean Read/Write: Read only Setting: Authorization.Identifications[Rfid].IsEnabled Type: Boolean Read/Write: Both Requires restart? Yes Setting: Authorization.Identifications[MobileApp].IsEnabled Type: Boolean Read/Write: Both Requires restart? Yes Setting: Authorization.Identifications[Sms].IsEnabled Type: Boolean Read/Write: Both Requires restart? Yes Setting: Authorization.Identifications[Pin].IsEnabled Type: Boolean Read/Write: Both Requires restart? Yes Setting: Authorization.Identifications[BankCard].IsEnabled Type: Boolean Read/Write: Both Requires restart? Yes Setting: Authorization.Identifications.MobileApp.Type Type: Enumeration; Allowed values: Pin, Rfid, Nfc, Sms, Vehicle15118, MobileApp, BankCard Read/Write: Read only Setting: Authorization.Identifications.Pin.DisplayOrder Type: Int32 Read/Write: Both Requires restart? Yes Setting: Authorization.Identifications.Pin.IsEnabled Type: Boolean Read/Write: Both Requires restart? Yes Setting: Authorization.Identifications.Pin.IsInstalled Type: Boolean Read/Write: Read only Setting: Authorization.Identifications.Pin.Type Type: Enumeration; Allowed values: Pin, Rfid, Nfc, Sms, Vehicle15118, MobileApp, BankCard Read/Write: Read only Setting: Authorization.LocalAuthorizeOffline Type: Boolean Read/Write: Both Requires restart? Yes Setting: Authorization.LocalPreAuthorize Type: Boolean Read/Write: Both Requires restart? Yes Setting: Authorization.Login.AppDownloadUrl Type: String Read/Write: Both Requires restart? Yes Setting: Authorization.Login.SmsNumber Type: String Read/Write: Both Requires restart? Yes Setting: Authorization.Login.SupportPage Type: String Read/Write: Both Requires restart? Yes Description: Address of support page, where customer can find information how to register to charging services Setting: Authorization.Login.SupportedApps Type: String Read/Write: Both Requires restart? Yes Description: List of supported application with which user can start charging. Use , character to create a list. List contains only names on app store. You can also list roaming applications. Setting: Authorization.OcppAuthorizationCacheEnabled Type: Boolean Read/Write: Both Requires restart? Yes Setting: Authorization.OcppLocalAuthListEnabled Type: Boolean Read/Write: Both Requires restart? Yes Setting: Authorization.OcppLocalAuthListMaxLength Type: Int32 Min: 10 Max: 5000 Read/Write: Both Requires restart? Yes Setting: Authorization.PlugAndChargeIDTag Type: String Read/Write: Both Requires restart? Yes Setting: Authorization.SendOcppLocalListMaxLength Type: Int32 Min: 10 Max: 5000 Read/Write: Both Requires restart? Yes Setting: Authorization.SessionRestoreCheckTimeout Type: String; Format: time (hh:mm:ss) Min: 00:00:01 Max: 00:10:00 Read/Write: Both Requires restart? Yes Setting: Authorization.SupportContact Type: String Read/Write: Both Requires restart? No Setting: Authorization.SwapRfidBytes Type: Boolean Read/Write: Both Requires restart? Yes Setting: Authorization.SingleSwipeStop Type: Boolean Read/Write: Both Requires restart? Yes Description: If true, then when card is swiped session is stopped without confirming it on the screen. If true, user cannot start two sessions with the same card Setting: Authorization.Type Type: Enumeration; Allowed values: PlugAndCharge, ChargerWhitelistOnly, CentralSystemOnly, ChargerWhitelistAndCentralSystem Read/Write: Both Requires restart? Yes Setting: CentralSystem.ChargerServer.ExternalIp Type: String Read/Write: Both Requires restart? Yes Setting: CentralSystem.ChargerServer.ExternalPort Type: Int32 Read/Write: Both Requires restart? Yes Setting: CentralSystem.ChargerServer.Port Type: Int32 Read/Write: Both Requires restart? Yes Setting: CentralSystem.ChargerServer.SOAPDynamicIPInterface Type: Enumeration; Allowed values: UseExternalIp, Ethernet, WiFi, Mobile Read/Write: Both Requires restart? Yes Setting: CentralSystem.ChargerServer.UseSsl Type: Boolean Read/Write: Both Requires restart? Yes **This setting cannot be changed from central system yet. It will be available in one of the future firmware updates Setting: CentralSystem.ChargerServer.WhiteListIPAddresses Type: String[] Read/Write: Both Requires restart? Yes Setting: CentralSystem.Client.AuthorizeCounterInterval Type: String; Format: time (hh:mm:ss) Min: 00:01:00 Max: 01:00:00 Read/Write: Both Requires restart? Yes Setting: CentralSystem.Client.CommunicationChecker.AfterChargingWaitInterval Type: String; Format: time (hh:mm:ss) Min: 00:00:01 Max: 02:00:00 Read/Write: Both Requires restart? Yes Setting: CentralSystem.Client.CommunicationChecker.NoCommunicationEthernetResetInterval Type: String; Format: time (hh:mm:ss) Min: 00:01:00 Max: 1.00:00:00 Read/Write: Both Requires restart? Yes Setting: CentralSystem.Client.CommunicationChecker.NoCommunicationResetInterval Type: String; Format: time (hh:mm:ss) Min: 00:01:00 Max: 7.00:00:00 Read/Write: Both Requires restart? Yes Setting: CentralSystem.Client.ConnectionTimeOut Type: String; Format: time (hh:mm:ss) Min: 00:00:02 Max: 00:05:00 Read/Write: Both Requires restart? Yes Setting: CentralSystem.Client.EventCounterInterval Type: String; Format: time (hh:mm:ss) Min: 00:01:00 Max: 01:00:00 Read/Write: Both Requires restart? Yes Setting: CentralSystem.Client.FirstSendingTimeout Type: String; Format: time (hh:mm:ss) Min: 00:00:01 Max: 00:02:00 Read/Write: Both Requires restart? Yes Setting: CentralSystem.Client.HeartbeatInterval Type: String; Format: time (hh:mm:ss) Min: 00:00:10 Max: 00:30:00 Read/Write: Both Requires restart? Yes Setting: CentralSystem.Client.MaxAuthorizeCalls Type: Int32 Min: 10 Max: 100 Read/Write: Both Requires restart? Yes Setting: CentralSystem.Client.MaxAuthorizeCounter Type: Int32 Min: 10 Max: 100 Read/Write: Both Requires restart? Yes Setting: CentralSystem.Client.MaxDataTransferCalls Type: Int32 Min: 10 Max: 100 Read/Write: Both Requires restart? Yes Setting: CentralSystem.Client.MaxDiagnosticsStatusCalls Type: Int32 Min: 10 Max: 100 Read/Write: Both Requires restart? Yes Setting: CentralSystem.Client.MaxEventCounter Type: Int32 Min: 50 Max: 1000 Read/Write: Both Requires restart? Yes Setting: CentralSystem.Client.MaxEventNotificationCalls Type: Int32 Min: 10 Max: 1000 Read/Write: Both Requires restart? Yes Setting: CentralSystem.Client.MaxFirmwareStatusCalls Type: Int32 Min: 10 Max: 100 Read/Write: Both Requires restart? Yes Setting: CentralSystem.Client.MaxMeterValuesCalls Type: Int32 Min: 10 Max: 2000 Read/Write: Both Requires restart? Yes Setting: CentralSystem.Client.MaxStartStopTransactionCalls Type: Int32 Min: 10 Max: 1000 Read/Write: Both Requires restart? Yes Setting: CentralSystem.Client.MaxStatusNotificationCalls Type: Int32 Min: 10 Max: 1000 Read/Write: Both Requires restart? Yes **This setting cannot be changed from central system yet. It will be available in one of the future firmware updates. But you can use a standard OCPP setting to list Meter Values Clock Aligned Setting: CentralSystem.Client.MeterValues.AlignedData Type: MeasurandType[] Read/Write: Both Requires restart? Yes Setting: CentralSystem.Client.MeterValues.AlignedDataInterval Type: String; Format: time (hh:mm:ss) Min: 00:01:00 Max: 01:00:00 Also allowed: 00:00:00 Read/Write: Both Requires restart? Yes **This setting cannot be changed from central system yet. It will be available in one of the future firmware updates. But you can use a standard OCPP setting to list Meter Values Setting: CentralSystem.Client.MeterValues.SampledData Type: MeasurandType[] Read/Write: Both Requires restart? Yes Setting: CentralSystem.Client.MeterValues.SampledDataInterval Type: String; Format: time (hh:mm:ss) Min: 00:00:05 Max: 00:30:00 Also allowed: 00:00:00 Read/Write: Both Requires restart? Yes Setting: CentralSystem.Client.NumRetries Type: Int32 Min: 1 Max: 10 Read/Write: Both Requires restart? Yes Setting: CentralSystem.Client.ObeyOcppNotificationRules Type: Boolean Read/Write: Both Requires restart? Yes Setting: CentralSystem.Client.RetryInterval Type: String; Format: time (hh:mm:ss) Min: 00:00:10 Max: 00:30:00 Read/Write: Both Requires restart? Yes Setting: CentralSystem.Client.WebSocketSendNullValues Type: Boolean Read/Write: Both Requires restart? Yes Description: If true, then null values are sending null in attribute values if value not defines. If false, then attributes are not send if value not defined. Select value based on central system implementation. Setting: CentralSystem.Client.ObeyOcppInfoFieldLength Type: Boolean Read/Write: Both Requires restart? Yes Description: If true, then Info field in status notification message is limited/trimmed to 50 characters as defined in OCPP specification. If false full/longer text is send. Selection depends on central system implementation. Setting: CentralSystem.Client.Servers.0.ClientCertificate Type: String Read/Write: Both Requires restart? Yes Setting: CentralSystem.Client.Servers.0.Protocol Type: Enumeration; Allowed values: Undefined, OCPP1_6S, OCPP1_6J Read/Write: Both Requires restart? Yes Setting: CentralSystem.Client.Servers.0.Url Type: String Read/Write: Both Requires restart? Yes Setting: CentralSystem.Client.WebSocketMessageTimeOut Type: String; Format: time (hh:mm:ss) Min: 00:00:02 Max: 00:01:00 Read/Write: Both Requires restart? Yes Setting: CentralSystem.Client.WebSocketPingInterval Type: String; Format: time (hh:mm:ss) Min: 00:00:10 Max: 00:30:00 Read/Write: Both Requires restart? Yes Setting: CentralSystem.CommunicationEnabled Type: Boolean Read/Write: Both Requires restart? Yes Setting: CentralSystem.Identity Type: String Read/Write: Both Requires restart? Yes **This setting cannot be changed from central system yet. It will be available in one of the future firmware updates. Setting: CentralSystem.VendorMessages Type: VendorMessageEnum[] Read/Write: Both Requires restart? Yes Setting: Dal.CleanupInterval Type: String; Format: time (hh:mm:ss) Read/Write: Both Requires restart? Yes Setting: Dal.MaxChargingAuthorizations Type: Int32 Min: 10 Max: 500 Read/Write: Both Requires restart? Yes Setting: Dal.MaxChargingReservations Type: Int32 Min: 10 Max: 100 Read/Write: Both Requires restart? Yes Setting: Dal.MaxChargingSessions Type: Int32 Min: 100 Max: 5000 Read/Write: Both Requires restart? Yes Setting: Dal.MaxEnergyConsumptions Type: Int32 Min: 100 Max: 10000 Read/Write: Both Requires restart? Yes Setting: Dal.MaxEvents Type: Int32 Min: 100 Max: 2000 Read/Write: Both Requires restart? Yes Setting: Dal.MaxLoadProfiles Type: Int32 Min: 100 Max: 5000 Read/Write: Both Requires restart? Yes Setting: Dal.MaxPowerSamples Type: Int32 Min: 100 Max: 10000 Read/Write: Both Requires restart? Yes Setting: Evses.0.Connectors.0.ConnectorId Type: Int32 Read/Write: Read only Description: Possible values: 1 for INCH HOME/PRO, 1,2 for INCH DUO Setting: Evses.0.Connectors.0.CustomMaxCurrent Type: Int32 Read/Write: Both Requires restart? No Setting: Evses.0.Connectors.0.CustomMaxCurrentSinglePhase Type: Int32 Read/Write: Both Requires restart? No Setting: Evses.0.Connectors.0.DefaultStateMachine Type: Enumeration; Allowed values: Iec61851, Iec15118, RenaultZeroReady, SchukoMicroswitch Read/Write: Both Requires restart? Yes Setting: Evses.0.Connectors.0.HardwareMaxCurrent Type: Int32 Read/Write: Read only Setting: Evses.0.Connectors.0.HardwareMaxVoltage Type: Int32 Read/Write: Read only Setting: Evses.0.Connectors.0.Locking.IsLidLockingInstalled Type: Boolean Read/Write: Read only Setting: Evses.0.Connectors.0.Locking.IsPlugLockingEnabled Type: Boolean Read/Write: Both Requires restart? Yes Setting: Evses.0.Connectors.0.Locking.IsPlugLockingInstalled Type: Boolean Read/Write: Read only Setting: Evses.0.Connectors.0.NumberOfPhases Type: Enumeration; Allowed values: One, Three Read/Write: Both Requires restart? Yes Setting: Evses.0.Connectors.0.StartChargingTimeoutSeconds Type: Int32 Min: 0 Max: 180 Read/Write: Both Requires restart? Yes Setting: Evses.0.Connectors.0.Type Type: Enumeration; Allowed values: SocketType2, CableType2, SocketHousehold Read/Write: Both Requires restart? Yes Setting: Evses.0.Connectors.0.UseDifferentLimitForSinglePhaseCharging Type: Boolean Read/Write: Both Requires restart? No Setting: Evses.0.EnableEVSEPauseCharging Type: Boolean Read/Write: Both Requires restart? Yes Setting: Evses.0.EvseCode Type: String Read/Write: Both Requires restart? Yes Setting: Evses.0.EvseProtocolId Type: Int32 Read/Write: Read only Setting: Evses.0.EvseId Type: Int32 Read/Write: Read only Description: Possible values: 1 for INCH HOME/PRO, 1,2 for INCH DUO Setting: Evses.0.LeakageDevice Type: String Read/Write: Read only Description: Possible values: None, BenderLeakageACDC Setting: Evses.0.GridConnection.ConnectedToASinglePhase Type: Boolean Read/Write: Both Requires restart? Yes Setting: Evses.0.GridConnection.EvseL1ConnectedToPhase Type: Enumeration; Allowed values: L1, L2, L3 Read/Write: Both Requires restart? Yes Setting: Evses.0.GridConnection.EvseL2ConnectedToPhase Type: Enumeration; Allowed values: L1, L2, L3 Read/Write: Both Requires restart? Yes Setting: Evses.0.GridConnection.EvseL3ConnectedToPhase Type: Enumeration; Allowed values: L1, L2, L3 Read/Write: Both Requires restart? Yes Setting: Evses.0.Meter.Address Type: String Read/Write: Both Requires restart? Yes Setting: Evses.0.Meter.MeterType Type: Enumeration; Allowed values: IntegratedAfe, AlgodueModbusTcp, IskraModbusRtu Read/Write: Both Requires restart? Yes Setting: Evses.0.Meter.SerialNumber Type: String Read/Write: Both Requires restart? Yes Setting: Evses.0.Overcurrent.0.Interval Type: Int32 Read/Write: Both Requires restart? Yes Setting: Evses.0.Overcurrent.0.Limit Type: Int32 Read/Write: Both Requires restart? Yes Setting: Evses.0.Overcurrent.1.Interval Type: Int32 Read/Write: Both Requires restart? Yes Setting: Evses.0.Overcurrent.1.Limit Type: Int32 Read/Write: Both Requires restart? Yes Setting: Evses.0.Overcurrent.2.Interval Type: Int32 Read/Write: Both Requires restart? Yes Setting: Evses.0.Overcurrent.2.Limit Type: Int32 Read/Write: Both Requires restart? Yes Setting: Evses.0.ParkingSensor.ParkingSensorEnabled Type: Boolean Read/Write: Both Requires restart? Yes Setting: Evses.0.ParkingSensor.ParkingSensorType Type: Enumeration; Allowed values: None, BuiltInCamera, CurrentLoopUnderParkingLot Read/Write: Both Requires restart? Yes Setting: Evses.0.SWOvercurrentProtectionEnabled Type: Boolean Read/Write: Both Requires restart? Yes Setting: Gui.ChargingModeTimeout Type: String; Format: time (hh:mm:ss) Min: 00:00:05 Max: 00:05:00 Read/Write: Both Requires restart? Yes **This setting cannot be changed from central system yet. It will be available in one of the future firmware updates. Setting: Gui.ChargingStatus.PrivateSlides Type: String[] Read/Write: Both Requires restart? Yes **This setting cannot be changed from central system yet. It will be available in one of the future firmware updates. Setting: Gui.ChargingStatus.PublicSlides Type: String[] Read/Write: Both Requires restart? Yes Setting: Gui.CommercialsTimeout Type: String; Format: time (hh:mm:ss) Min: 00:00:02 Max: 00:02:00 Read/Write: Both Requires restart? Yes **This setting cannot be changed from central system yet. It will be available in one of the future firmware updates. Setting: Gui.Cultures Type: String[] Read/Write: Both Requires restart? Yes Setting: Gui.Currency Type: String Read/Write: Both Requires restart? Yes Setting: Gui.DepartureScreenTimeout Type: String; Format: time (hh:mm:ss) Min: 00:00:05 Max: 00:05:00 Read/Write: Both Requires restart? Yes Setting: Gui.EnableCommercials Type: Boolean Read/Write: Both Requires restart? Yes Setting: Gui.EnableDisplayingPrices Type: Boolean Read/Write: Both Requires restart? Yes Setting: Gui.EnableSettingDepartureTime Type: Boolean Read/Write: Both Requires restart? Yes Setting: Gui.GuiFlavour Type: Enumeration; Allowed values: Demo, Sonnen, SingleSocketPrivate, SingleSocketPublic Read/Write: Both Requires restart? Yes Setting: Gui.ChargePointFriendlyCode Type: String Read/Write: Both Requires restart? Yes Description: Defines friendly code of the charge point as defined in central system. This code is specially used in credit card payment, to mark charger in the cluster. Setting: Gui.ScreenSaverBacklightMode Type: Enumeration; Allowed values: Blinking, SteadyOn, SteadyOff Read/Write: Both Requires restart? Yes Setting: Gui.ScreenSaverLcdOffInterval Type: String; Format: time (hh:mm:ss) Min: 00:00:01 Max: 00:00:10 Read/Write: Both Requires restart? Yes Setting: Gui.ScreenSaverLcdOnInterval Type: String; Format: time (hh:mm:ss) Min: 00:00:01 Max: 00:00:10 Read/Write: Both Requires restart? Yes Setting: Gui.ScreenSaverTimeout Type: String; Format: time (hh:mm:ss) Min: 00:00:10 Max: 00:02:00 Read/Write: Both Requires restart? Yes Setting: Gui.ShowConnectivityStatus Type: Boolean Read/Write: Both Requires restart? Yes Setting: Gui.SupportData.PhoneNumber Type: String Read/Write: Both Requires restart? Yes Description: Phone number of charge point operator support. Is displayed to the customer when clicked on help icon on LCD display if available. Setting: Gui.SupportData.Url Type: String Read/Write: Both Requires restart? Yes Description: Web page charge point operator support. Is displayed to the customer when clicked on help icon on LCD display if available. Setting: Network.Gsm.Apn Type: String Read/Write: Both Requires restart? Yes Setting: Network.Gsm.IsEnabled Type: Boolean Read/Write: Both Requires restart? Yes Setting: Network.Gsm.IsInstalled Type: Boolean Read/Write: Read only Setting: Network.Gsm.Password Type: String Read/Write: Both Requires restart? Yes Setting: Network.Gsm.UserName Type: String Read/Write: Both Requires restart? Yes Setting: Network.Lan.IP4.Address Type: String; Format: must be IP Address or empty Read/Write: Both Requires restart? Yes Setting: Network.Lan.IP4.DhcpEnabled Type: Boolean Read/Write: Both Requires restart? Yes Setting: Network.Lan.IP4.Gateway Type: String; Format: must be IP Address or empty Read/Write: Both Requires restart? Yes Setting: Network.Lan.IP4.Netmask Type: String; Format: must be IP Address or empty Read/Write: Both Requires restart? Yes Setting: Network.Lan.IP4.ObtainDnsServerAddressAutomatically Type: Boolean Read/Write: Both Requires restart? Yes Setting: Network.Lan.IP4.PrimaryDns Type: String; Format: must be IP Address or empty Read/Write: Both Requires restart? Yes Setting: Network.Lan.IP4.SecondaryDns Type: String; Format: must be IP Address or empty Read/Write: Both Requires restart? Yes Setting: Network.Wifi.AuthenticationType Type: Enumeration; Allowed values: Open, Shared, WpaPsk, Wpa2Psk Read/Write: Both Requires restart? Yes Setting: Network.Wifi.EncryptionType Type: Enumeration; Allowed values: None, Wep, Tkip, Aes, TkipAes Read/Write: Both Requires restart? Yes Setting: Network.Wifi.IsEnabled Type: Boolean Read/Write: Both Requires restart? Yes Setting: Network.Wifi.IsInstalled Type: Boolean Read/Write: Read only Setting: Network.Wifi.OperationMode Type: Enumeration; Allowed values: Gateway, Client Read/Write: Both Requires restart? Yes Setting: Network.Wifi.Password Type: String Read/Write: Both Requires restart? Yes Note: This value is obfuscated on read. Setting: Network.Wifi.Ssid Type: String Read/Write: Both Requires restart? Yes Setting: Network.Wifi.Wan.Address Type: String; Format: must be IP Address or empty Read/Write: Both Requires restart? Yes Setting: Network.Wifi.Wan.DhcpEnabled Type: Boolean Read/Write: Both Requires restart? Yes Setting: Network.Wifi.Wan.Gateway Type: String; Format: must be IP Address or empty Read/Write: Both Requires restart? Yes Setting: Network.Wifi.Wan.Netmask Type: String; Format: must be IP Address or empty Read/Write: Both Requires restart? Yes Setting: Network.Wifi.Wan.ObtainDnsServerAddressAutomatically Type: Boolean Read/Write: Both Requires restart? Yes Setting: Network.Wifi.Wan.PrimaryDns Type: String; Format: must be IP Address or empty Read/Write: Both Requires restart? Yes Setting: Network.Wifi.Wan.SecondaryDns Type: String; Format: must be IP Address or empty Read/Write: Both Requires restart? Yes Setting: Network.TimeServers Type: String Read/Write: Both Requires restart? Yes Description: Can edit array of NTP servers. Address time servers by spedifiying index. To change first one use: Network.TimeServers[0] Setting: Operators Type: OperatorsSettings Read/Write: Both Requires restart? No Setting: PowerManagement.FrequencyControl.IsEnabled Type: Boolean Read/Write: Both Requires restart? Yes **This setting cannot be changed from central system yet. It will be available in one of the future firmware updates. Setting: PowerManagement.FrequencyControl.Limits Type: FrequencyControlLimit[] Read/Write: Both Requires restart? No Setting: PowerManagement.MaxOutputCurrentWhenClusterCommFails Type: Int32 Read/Write: Both Requires restart? No Setting: PowerManagement.PrimaryMaster.Address Type: String; Format: must be IP Address Read/Write: Both Requires restart? Yes Setting: PowerManagement.PrimaryMaster.IsEnabled Type: Boolean Read/Write: Both Requires restart? Yes Setting: PowerManagement.PrimaryMaster.Port Type: Int32 Read/Write: Both Requires restart? Yes Setting: PowerManagement.SecondaryMaster.Address Type: String; Format: must be IP Address Read/Write: Both Requires restart? Yes Setting: PowerManagement.SecondaryMaster.IsEnabled Type: Boolean Read/Write: Both Requires restart? Yes Setting: PowerManagement.SecondaryMaster.Port Type: Int32 Read/Write: Both Requires restart? Yes Setting: PowerManagement.ShortStatusSendInterval Type: String; Format: time (hh:mm:ss) Read/Write: Both Requires restart? Yes Setting: PowerManagement.StatusSendInterval Type: String; Format: time (hh:mm:ss) Read/Write: Both Requires restart? Yes Setting: PowerManagement.ProfileSettings.RecurringProfileRandomDelay Type: String; Format: time (hh:mm:ss) Read/Write: Both Requires restart? Yes Description: Defines time interval in which random value is selected to be used as adoption delay when schedule increases target value from lower to higher value. Setting: PowerManagement.ProfileSettings.ChargingModeFlavour Type: String; Possible values: ProfilesActiveInSmartAndFastMode, ProfilesActiveOnlyInSmartMode Read/Write: Both Requires restart? Yes Description: Defines if charging mode (fast or smart) has an effect on when load schedule is applied Setting: PowerManagement.ProfileSettings.AllowRemoteProfiles Type: Boolean Read/Write: Both Requires restart? Yes Description: If false then OCPP SetProfile will be rejected by the charge point Setting: PowerManagement.ProfileSettings.RealignProfileZero Type: Boolean Read/Write: Both Requires restart? Yes Description: Profile 0 (zero) is used as default weekly recurring profile. Since weekly profile is using local time, profile needs to be rescheduled twice per year when date time saving kicks in. Set this one to true if you want that profile is corrected automatically when daylight saving kicks in. Setting: Session.DefaultChargingMode Type: Enumeration; Allowed values: Fast, Smart Read/Write: Both Requires restart? Yes Setting: Session.DefaultDepartureOffset Type: String; Format: time (hh:mm:ss) Min: 00:10:00 Max: 23:00:00 Read/Write: Both Requires restart? Yes Setting: Session.EnergyConsumptionStoreInterval Type: String; Format: time (hh:mm:ss) Min: 00:00:30 Max: 01:00:00 Read/Write: Both Requires restart? Yes Setting: Session.PowerStoreInterval Type: String; Format: time (hh:mm:ss) Min: 00:00:30 Max: 01:00:00 Read/Write: Both Requires restart? Yes Setting: ModbusOp.Enabled Type: Boolean Read/Write: Both Requires restart? Yes Description: Defines if Modbus interface/service(Modbus TCP server on port 502) is enabled on the charger. Setting: ModbusOp.UseSsl Type: Boolean Read/Write: Both Requires restart? Yes Description: Defines if Modbus interface/service (Modbus TCP server on port 502) is available only through secure connection.Please note that root certificate for Modbus communication and client certificate thumprint have to be provided. If not provided interface will not work. Root certificate can be uploaded only through web interface. Setting: ModbusOp.CertThumbprint Type: String Read/Write: Both Requires restart? Yes Description: Defines client certificate thumbprint used for additional authentication for the Modbus TCP client trying to connect to the charger (Modbus TCP server on port 502). Setting: ModbusOp.CommunicationLostFallbackCurrent Type: Int32 Read/Write: Both Requires restart? Yes Description: Defines fallback current if in fallback timeout interval no messages from client received (no commands or readouts) to the charger (Modbus TCP server on port 502). Setting: ModbusOp.CommunicationLostFallbackTimeout Type: Int32 Read/Write: Both Requires restart? Yes Description: Defines timeout in seconds where if no communication from Modbus TCP client, fallback process will be triggered (Modbus TCP server on port 502). Setting: ModbusPM.Enabled Type: Boolean Read/Write: Both Requires restart? Yes Description: Defines if Modbus interface/service(Modbus TCP server on port 503 - power management service) is enabled on the charger. Setting: ModbusPM.UseSsl Type: Boolean Read/Write: Both Requires restart? Yes Description: Defines if Modbus interface/service (Modbus TCP server on port 503 - power management service) is available only through secure connection.Please note that root certificate for Modbus communication and client certificate thumprint have to be provided. If not provided interface will not work. Root certificate can be uploaded only through web interface. Setting: ModbusPM.CertThumbprint Type: String Read/Write: Both Requires restart? Yes Description: Defines client certificate thumbprint used for additional authentication for the Modbus TCP client trying to connect to the charger (Modbus TCP server on port 503 - power management service). Setting: Time.TimeZoneRegion Type: String Read/Write: Both Requires restart? Yes Setting: Web.AllowAnonymousAccess Type: Boolean Read/Write: Both Requires restart? Yes Setting: Web.Port Type: Int32 Read/Write: Both Requires restart? Yes Setting: Web.RequireClientCertificate Type: Boolean Read/Write: Both Requires restart? Yes Setting: Web.UseSsl Type: Boolean Read/Write: Both Requires restart? Yes Setting: Aux.DigitalIOs.ParkingOccupiedEnabled Type: Boolean Read/Write: Both Requires restart? Yes Description: If true then one of the I/O inputs is designated to monitor if parking space is occupied Setting: Aux.DigitalIOs.Parking1Occupied Type: Int32 Read/Write: Both Requires restart? Yes Description: Defines input pin on I/O terminal, that is designated for connector 1 parking lot monitoring. Use values 1,2,3 or 4 in the case of INCH DUO or 1 or 2 in the case of INCH. Setting: Aux.DigitalIOs.Parking2Occupied Type: Int32 Read/Write: Both Requires restart? Yes Description: Defines input pin on I/O terminal, that is designated for connector 2 parking lot monitoring. Please note, that this one is enabled only on INCH DUO (not on INCH HOME or PRO). Use values 1,2,3 or 4 Setting: Aux.DigitalIOs.ParkingOccupiedNormallyOff Type: Boolean Read/Write: Both Requires restart? Yes Description: It is related to parking detection. If true then I/O input logic is reversed. 0V on input means logical true and 12VDC on input means logical false. Setting: Aux.DigitalIOs.DecreaseChargingPowerEnabled Type: Boolean Read/Write: Both Requires restart? Yes Description: If true then one of the I/O inputs is designated to monitor if charging current should be decreased on pin value change Setting: Aux.DigitalIOs.DecreaseChargingPowerNormallyOff Type: Boolean Read/Write: Both Requires restart? Yes Description: It is related to current decrease. If true then I/O input logic is reversed. 0V on input means logical true and 12VDC on input means logical false. Setting: Aux.DigitalIOs.DecreaseChargingPowerInput Type: Int32 Read/Write: Both Requires restart? Yes Description: Defines input pin on I/O terminal, that is designated for current decrease monitoring. Use values 1,2,3 or 4 in the case of INCH DUO or 1 or 2 in the case of INCH. Setting: Aux.DecreaseMaxCurrent Type: Int32 Read/Write: Both Requires restart? Yes Description: Defines to which target value charger output should be set (max charging current), when logical true is detected on monitoring pin. In the case of logical false, connector is not limited by external signals. Setting: Aux.DecreaseMaxCurrent Type: Int32 Read/Write: Both Requires restart? Yes Description: Defines to which target value charger output should be set (max charging current), when logical true is detected on monitoring pin. In the case of logical false, connector is not limited by external signals. Setting: Payment.CreditCard.IsEnabled Type: Boolean Read/Write: Both Requires restart? Yes Description: If true then credit card payment is enabled. Make sure that credit card payment is selected also in the list of identifications. This can be enabled on payment cluster slave or master Setting: Payment.CreditCard.Terminal.IsInstalled Type: Boolean Read/Write: Readonly Description: If true, then charger has installed payment terminal Setting: Payment.CreditCard.Terminal.IsEnabled Type: Boolean Read/Write: Both Requires restart? Yes Description: If true then credit card payment terminal is enabled. Only payment masters, where payment terminals installed need to have this setting enabled. If disabled then payment with credit card is not possible on this charger. Setting: Payment.CreditCard.Terminal.Ip Type: String Format: IPv4 xxx.xxx.xxx.xxx Read/Write: Both Requires restart? Yes Description: Ip v4 address of payment terminal. Should always be 172.25.2.159 since is set by charger DhcpEnabled Setting: Payment.CreditCard.Terminal.Port Type: Int32 Read/Write: Redonly Description: Should be always 3183, since this port is used for communication Setting: Payment.CreditCard.Terminal.ConnectTimeout Type: String, Use time format: xx:xx:xx Read/Write: Both Requires restart? Yes Description: Communication timeout when central system communicating with payment terminal. Use values between 00:00:05 and 00:00:30. Since internal communication is used, timeouts should not occur. Setting: Payment.CreditCard.Terminal.NumberOfRetriesForFailedTransactions Type: Int32 Read/Write: Both Requires restart? Yes Description: Defines how many times charger should try to send settlemement message in the case that communication with payment providers failed (issues on Mobile communication or at payment provider). After retries, settlements will not be send anymore and customer will not be charged. Setting: Payment.CreditCard.Terminal.NumberOfRetriesForFailedTransactions Type: String, Use time format: xx:xx:xx Read/Write: Both Requires restart? Yes Description: Defines time interval in which charger should try to send settlemement messages in the case that communication with payment providers failed (issues on Mobile communication or at payment provider). We propose that this interval multiplied with number of retries last at least 24 hours. Setting: Payment.CreditCard.Currency Type: String Read/Write: Both Requires restart? Yes Description: Currency is used when payment terminal communicates with payment provider: currently this currencies are supported: EUR, USD, GBP, HRK, CHF Setting: Payment.CreditCard.PreauthorizationAmountACCharging Type: Float Read/Write: Both Requires restart? Yes Description: Defines funds that are reserved from customer back account, before chartging starts on AC connector in this payment cluster. VAT should be included. Setting: Payment.CreditCard.PreauthorizationAmountDCCharging Type: Float Read/Write: Both Requires restart? Yes Description: Defines funds that are reserved from customer back account, before chartging starts on DC connector in this payment cluster. VAT should be included. Setting: Payment.CreditCard.PreauthorizationVAT Type: Float Read/Write: Both Requires restart? Yes Description: Defines VAT in percentage. Is used in communication with a payment provider. Setting: Payment.CreditCard.PreauthorizationWithoutTransactionTimeout Type: String, Use time format: xx:xx:xx Read/Write: Both Requires restart? Yes Description: Defines interval in which reserved funds should be automatically released in the case that customer does not execute charging, but has executed card swipe. We recommend to use values higer that 00:05:00 Setting: Payment.CreditCard.InvoiceEndpoint Type: String Read/Write: Both Requires restart? Yes Description: If customer needs to get invoice for credit card payment, then charger can display web address where to download it. Ocean support this. Use this pattern for your Ocean instance: https://[your Ocean web app address]/#/portal/receiptdownload Setting: Payment.CreditCard.MasterChargerCode Type: String Read/Write: Both Requires restart? Yes Description: ID of the payment master charger as it is written on the charger. Users are directed from payment slave chargers to master charger to execute payment Setting: Payment.CreditCard.IsPaymentMaster Type: Boolean Read/Write: Both Requires restart? Yes Description: If this setting is true, charger will display Pay here button on DUO first screen Setting: Payment.Pricing.Url Type: String Read/Write: Both Requires restart? Yes Description: Defines link on external web page where pricing information can be found. Use this setting in the case Payment.Pricing.Text or Payment.Pricing.Items are not defined Setting: Payment.Pricing.Text Type: JSON string Read/Write: Both Requires restart? Yes Description: Defines pricing description in the text form. Multiple languages can be suported. Please use this JSON structure: { "Culture": "en-GB", "Text": "Prices are 0,5 Eur to start charging and additional 0,02Eur/kWh" }, { "Culture": "sl-SI", "Text": "Zacetek polnjenja stane 0,5 Eur in nato 0,02 Eur/kWh" } Setting: Payment.Pricing.Items Type: JSON string Read/Write: Both Requires restart? Yes Description: Defines pricing in structured way - with standard price items. Please use this JSON structure: { "Name": [ { "Culture": "", "Text": "Energy" }, { "Culture": "sl-SI", "Text": "Energija" } ], "Unit": "kWh", "RateWithVAT": 0.2 }, { "Name": [ { "Culture": "", "Text": "One time fee" }, { "Culture": "sl-SI", "Text": "Pristojbnina" } ], "Unit": "", "RateWithVAT": 0.5 } Setting: BuildingPowerSupplyLimits.LoadGuard.IsInstalled Type: Boolean Read/Write: Both Requires restart? Yes Description: Defines if LoadGuard is installed. If false, then power management will not take into account measurements received from LoadGuard Setting: BuildingPowerSupplyLimits.LoadGuard.LoadGuardSerial Type: String Read/Write: Both Requires restart? Yes Description: Serial number of LoadGuard. In the case that LoadGuard type is an external meter, then this value can be empty Setting: BuildingPowerSupplyLimits.LoadGuard.StaleInterval Type: String, Use time format: xx:xx:xx Read/Write: Both Requires restart? Yes Description: Monitoring interval in which LoadGuard should send data, otherwise fallback procedure will trigger Setting: BuildingPowerSupplyLimits.LoadGuard.StaleInterval Type: String, Possible values: Etrel, Algodue_UPM209, Algodue_UEM80_4D Read/Write: Both Requires restart? Yes Description: Defines a type of LoadGuard device Setting: BuildingPowerSupplyLimits.LoadGuard.CounterData.Ip Type: String, IP v4 format: xxx.xxx.xxx.xxx Read/Write: Both Requires restart? Yes Description: IP v4 address of external meter where Modbus TCP service is available. Should be set only if this meter types are used: Algodue_UPM209, Algodue_UEM80_4D Setting: BuildingPowerSupplyLimits.LoadGuard.CounterData.Port Type: Int32 Read/Write: Both Requires restart? Yes Description: TCP Port on endpoint (meter IP address) where Modbus service available Setting: BuildingPowerSupplyLimits.MaxBuildingCurrentL1 Type: Float Read/Write: Both Requires restart? Yes Description: Buliding limit on phase L1. Unit is Amper. Setting: BuildingPowerSupplyLimits.MaxBuildingCurrentL2 Type: Float Read/Write: Both Requires restart? Yes Description: Buliding limit on phase L2. Unit is Amper. Setting: BuildingPowerSupplyLimits.MaxBuildingCurrentL3 Type: Float Read/Write: Both Requires restart? Yes Description: Buliding limit on phase L3. Unit is Amper. Setting: BuildingPowerSupplyLimits.MaxClusterCurrentL1 Type: Float Read/Write: Both Requires restart? Yes Description: Charging cluster limit on phase L1. Unit is Amper. Setting: BuildingPowerSupplyLimits.MaxClusterCurrentL2 Type: Float Read/Write: Both Requires restart? Yes Description: Charging cluster limit on phase L2. Unit is Amper. Setting: BuildingPowerSupplyLimits.MaxClusterCurrentL3 Type: Float Read/Write: Both Requires restart? Yes Description: Charging cluster limit on phase L3. Unit is Amper. Setting: BuildingPowerSupplyLimits.MaxClusterCurrentWhenLoadGuardCommFailsL1 Type: Float Read/Write: Both Requires restart? Yes Description: Fallback cluster limitation on phase L1 if communication with Load Guard fails (no data reveiced in monitoring period). Unit is Amper. Setting: BuildingPowerSupplyLimits.MaxClusterCurrentWhenLoadGuardCommFailsL2 Type: Float Read/Write: Both Requires restart? Yes Description: Fallback cluster limitation on phase L2 if communication with Load Guard fails (no data reveiced in monitoring period). Unit is Amper. Setting: BuildingPowerSupplyLimits.MaxClusterCurrentWhenLoadGuardCommFailsL3 Type: Float Read/Write: Both Requires restart? Yes Description: Fallback cluster limitation on phase L3 if communication with Load Guard fails (no data reveiced in monitoring period). Unit is Amper.